Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Arh Hig Rada Toksikol ; 75(1): 41-50, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38548384

ABSTRACT

Healthcare workers handling antineoplastic drugs (ADs) in preparation units run the risk of occupational exposure to contaminated surfaces and associated mutagenic, teratogenic, and oncogenic effects of those drugs. To minimise this risk, automated compounding systems, mainly robots, have been replacing manual preparation of intravenous drugs for the last 20 years now, and their number is on the rise. To evaluate contamination risk and the quality of the working environment for healthcare workers preparing ADs, we applied the Failure Mode Effects and Criticality Analysis (FMECA) method to compare the acceptable risk level (ARL), based on the risk priority number (RPN) calculated from five identified failure modes, with the measured risk level (MRL). The model has shown higher risk of exposure with powdered ADs and containers not protected by external plastic shrink film, but we found no clear difference in contamination risk between manual and automated preparation. This approach could be useful to assess and prevent the risk of occupational exposure for healthcare workers coming from residual cytotoxic contamination both for current handling procedures and the newly designed ones. At the same time, contamination monitoring data can be used to keep track of the quality of working conditions by comparing the observed risk profiles with the proposed ARL. Our study has shown that automated preparation may have an upper hand in terms of safety but still leaves room for improvement, at least in our four hospitals.


Subject(s)
Antineoplastic Agents , Occupational Exposure , Humans , Health Care Sector , Antineoplastic Agents/analysis , Occupational Exposure/adverse effects , Occupational Exposure/prevention & control , Occupational Exposure/analysis , Hospitals , Health Personnel , Environmental Monitoring/methods
2.
Molecules ; 29(3)2024 Jan 30.
Article in English | MEDLINE | ID: mdl-38338382

ABSTRACT

Despite the considerable steps taken in the last decade in the context of antineoplastic drug (AD) handling procedures, their mutagenic effect still poses a threat to healthcare personnel actively involved in compounding and administration units. Biological monitoring procedures usually require large volumes of sample and extraction solvents, or do not provide adequate sensitivity. It is here proposed a fast and automated method to evaluate the urinary levels of cyclophosphamide and iphosphamide, composed of a miniaturized solid phase extraction (µSPE) followed by ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) analysis. The extraction procedure, developed through design of experiments (DoE) on the ePrep One Workstation, required a total time of 9.5 min per sample, with recoveries of 77-79% and a solvent consumption lower than 1.5 mL per 1 mL of urine sample. Thanks to the UHPLC-MS/MS method, the limits of quantification (LOQ) obtained were lower than 10 pg/mL. The analytical procedure was successfully applied to 23 urine samples from compounding wards of four Italian hospitals, which resulted in contaminations between 27 and 182 pg/mL.


Subject(s)
Antineoplastic Agents , Occupational Exposure , Ifosfamide , Tandem Mass Spectrometry/methods , Liquid Chromatography-Mass Spectrometry , Biological Monitoring , Cyclophosphamide , Chromatography, High Pressure Liquid/methods , Solid Phase Extraction , Solvents
3.
Arh Hig Rada Toksikol ; 74(3): 187-197, 2023 Sep 01.
Article in English | MEDLINE | ID: mdl-37791676

ABSTRACT

Antineoplastic drugs (ADs) are essential tools in cancer treatment, but their cytotoxicity poses a risk to workers involved in their handling. In a hospital environment fundamental strategies for minimising exposure involve proper use of safety cabinets and closed-circuit transfer devices, along with personnel training and increased awareness of risks. However, medical gloves remain the first line of defence. In this respect the evaluation of glove materials and best choices can improve hospital safety management and prevent potential hazards and long-term consequences. The aim of this study was to assess contamination of gloves in samples taken from AD administration and preparation units of nine Italian hospitals and to raise awareness of the importance of evaluating chemico-physical properties of gloves. Our findings show that 33 % of the analysed gloves were positive for at least one AD, with contaminations ranging from 0.6 to 20,729 pg/ cm2. We proposed the alert glove values (AGVs) for each AD as a limit value for contamination assessment and good practice evaluation. Our findings also point to multiple AD contamination (43 % of positive findings in preparation units), calculated as total AGV (AGV-T), and confirm that gloves should be replaced after 30 min of AD handling, based on cumulative permeation and area under the curve (AUC), to maintain safety and limit dermal exposure.


Subject(s)
Antineoplastic Agents , Occupational Exposure , Humans , Health Care Sector , Antineoplastic Agents/adverse effects , Occupational Exposure/prevention & control , Occupational Exposure/analysis , Hospitals , Gloves, Protective
4.
Molecules ; 28(14)2023 Jul 16.
Article in English | MEDLINE | ID: mdl-37513313

ABSTRACT

Formaldehyde (FA) is a toxic compound and a human carcinogen. Regulating FA-releasing substances in commercial goods is a growing and interesting topic: worldwide production sectors, like food industries, textiles, wood manufacture, and cosmetics, are involved. Thus, there is a need for sensitive, economical, and specific FA monitoring tools. Solid-phase microextraction (SPME), with O-(2,3,4,5,6-pentafluorobenzyl)-hydroxylamine (PFBHA) on-sample derivatization and gas chromatography, is proposed for FA monitoring of real-life samples. This study reports the use of polydimethylsiloxane (PDMS) as a sorbent phase combined with innovative commercial methods, such as multiple SPME (MSPME) and cooling-assisted SPME, for FA determination. Critical steps, such as extraction and sampling, were evaluated in method development. The derivatization was performed at 60 °C for 30 min, followed by 15 min sampling at 10 °C, in three cycles (SPME Arrow) or six cycles (SPME). The sensitivity was satisfactory for the method's purposes (LOD-LOQ at 11-36 ng L-1, and 8-26 ng L-1, for SPME and SPME Arrow, respectively). The method's linearity ranges from the lower LOQ at trace level (ng L-1) to the upper LOQ at 40 mg L-1. The precision range was 5.7-10.2% and 4.8-9.6% and the accuracy was 97.4% and 96.3% for SPME and SPME Arrow, respectively. The cooling MSPME set-up applied to real commercial goods provided results of quality comparable to previously published data.

5.
ACS Omega ; 8(17): 15397-15405, 2023 May 02.
Article in English | MEDLINE | ID: mdl-37151501

ABSTRACT

Trimellitic, phthalic, and maleic anhydrides are important building blocks to produce polymers and additives, such as plasticizers. In humans, the exposure to these compounds can cause several health issues. In European Union and USA, their presence in substances and mixtures is restricted by CLP Regulation (no. 1272/2008) and HCS/HazCom 2012, respectively, but no information about the corresponding acids is reported. For this reason, a selective method to determine anhydrides in mixtures, in the presence of acids, could be interesting. Nowadays, methods in the literature are either not selective or use explosive and toxic reagents (as diazomethane). In this work, an innovative, greener, and safer method for the simultaneous recognition and quantification of anhydrides and acids, via direct injection gas chromatography-mass spectrometry, is developed. The sample pretreatment consists in selective esterification with absolute ethanol on the anhydride, followed by a treatment with boron trifluoride-methanol for the methylation of remaining carboxylic groups. The optimization of the functionalization, a crucial step of the method, was optimized by experimental design. The limit of detection-limit of quantification (LOD-LOQ) values for trimellitic, phthalic, and maleic anhydrides are 0.31-0.93, 0.47-1.41, and 0.06-0.18 µg/mL, respectively.

SELECTION OF CITATIONS
SEARCH DETAIL
...